<%NUMBERING1%>.<%NUMBERING2%>.<%NUMBERING3%> PRTG Manual: SNMP Custom Advanced Sensor
The SNMP Custom Advanced sensor monitors numerical values returned by one or more specific Object Identifiers (OIDs) using Simple Network Management Protocol (SNMP).
- It can show numerical values at given OIDs on an SNMP device in up to 10 different channels.
Which channels the sensor actually shows might depend on the monitored device and the sensor setup.

SNMP Custom Advanced Sensor
Click here to enlarge: http://media.paessler.com/prtg-screenshots/snmp_custom_advanced.png
- Note: It might not work to query data from a probe device via SNMP (querying localhost, 127.0.0.1, or ::1). Add this device to PRTG with the IP address that it has in your network and create the SNMP sensor on this device instead.
- Knowledge Base: How do I find out what OID I need to use for a custom sensor?
- Important notice: Currently, this sensor type is in beta status. The methods of operating can change at any time, as well as the available settings. Do not expect that all functions will work properly, or that this sensor works as expected at all. Be aware that this type of sensor can be removed again from PRTG at any time.
- For a general introduction to the technology behind SNMP, please see the manual section Monitoring via SNMP.
The Add Sensor dialog appears when adding a new sensor on a device manually. It only shows the setting fields that are imperative for creating the sensor. Therefore, you will not see all setting fields in this dialog. You can change (nearly) all settings in the sensor's Settings tab later.
The following settings for this sensor differ in the 'Add Sensor' dialog in comparison to the sensor's settings page:
OID values |
|
---|---|
Value Type |
Select the expected numeric type of the results at the given OID. Choose between:
Once a sensor is created, you cannot change this value. It is shown for reference purposes only. If you need to change this, please add the sensor anew. |
Sensor Channel #2 – #10 |
You can create up to 10 different sensor channels for this sensor. You have to define at least one data channel, so you will see all available settings for Sensor Channel #1 without enabling it manually. Additionally you can define Sensor Channel #2 up to Sensor Channel #10. To do so, choose between:
Once a sensor is created, you cannot change this value. It is shown for reference purposes only. If you need to change this, please add the sensor anew. It is not possible to enable or disable sensor channels after creation of this sensor! |
On the details page of a sensor, click on the Settings tab to change its settings.
Note: Usually, a sensor connects to the IP Address or DNS Name of the parent device on which you created this sensor. See the Device Settings for details. For some sensor types, you can define the monitoring target explicitly in the sensor settings. Please see below for details on available settings.
Basic Sensor Settings |
|
---|---|
Sensor Name |
Enter a meaningful name to identify the sensor. By default, PRTG shows this name in the device tree, as well as in alarms, logs, notifications, reports, maps, libraries, and tickets. |
Parent Tags |
Shows Tags that this sensor inherits from its parent device, group, and probe. This setting is shown for your information only and cannot be changed here. |
Tags |
Enter one or more Tags, separated by space or comma. You can use tags to group sensors and use tag–filtered views later on. Tags are not case sensitive. We recommend that you use the default value. You can add additional tags to it, if you like. Other tags are automatically inherited from objects further up in the device tree. These are visible above as Parent Tags. |
Priority |
Select a priority for the sensor. This setting determines where the sensor is placed in sensor lists. Top priority is at the top of a list. Choose from one star (low priority) to five stars (top priority). |
OID values |
|
---|---|
Sensor Channel #x Name |
Enter a name for the channel in which the sensor shows the results at the given OID. Please enter a string. |
Sensor Channel #x OID |
Enter the OID of the SNMP object you want to receive numerical data from. Note: Most OIDs begin with 1.3.6.1. However, entering OIDs starting with 1.0, or 1.1, or 1.2 is also allowed. If you want to disable the validation of your entry during your typing entirely, add the string norfccheck: to the beginning of your OID, for example, norfccheck:2.0.0.0.1. |
Sensor Channel #x Value Type |
Shows the value type of the numerical data that this sensor receives from the given OID. Once a sensor is created, you cannot change this value. It is shown for reference purposes only. If you need to change this, please add the sensor anew. |
Sensor Channel #x Unit |
Define the unit of the numerical data that this sensor receives from the given OID. Choose between:
For more information about the available units, please refer to the PRTG Application Programming Interface (API) Definition for custom sensors. |
Sensor Channel #x Custom Unit |
This setting is only visible if you select the Custom unit option above. Define a unit for the channel value. Please enter a string. |
Sensor Channel #x Value Lookup |
This setting is only visible if you select the Value Lookup option above. Choose a lookup file that you want to use with this channel. |
Sensor Channel #y |
This field shows the option you chose for this channel in the Add Sensor dialog, Enable or Disable. Once a sensor is created, you cannot change this value. It is shown for reference purposes only. If you need to change this, please add the sensor anew. If you created this channel, you can define the settings of this channel as described above. |
Sensor Display |
|
---|---|
Primary Channel |
Select a channel from the list to define it as the primary channel. In the device tree, the last value of the primary channel will always be displayed below the sensor's name. The available options depend on what channels are available for this sensor. Note: You can set another primary channel later by clicking on the pin symbol of a channel in the sensor's Overview tab. |
Chart Type |
Define how different channels will be shown for this sensor.
|
Stack Unit |
This setting is only available if stacked graphs are selected above. Choose a unit from the list. All channels with this unit will be stacked on top of each other. By default, you cannot exclude single channels from stacking, if they use the selected unit. However, there is an advanced procedure to do so. |
By default, all following settings are inherited from objects higher in the hierarchy and should be changed there, if necessary. Often, best practice is to change them centrally in the Root group's settings. To change a setting only for this object, disable inheritance by clicking on the check mark before the corresponding setting name. You will then see the options described below.
Scanning Interval |
|
---|---|
Scanning Interval |
Select a scanning interval (seconds, minutes, or hours) from the list. The scanning interval determines the time the sensor waits between two scans. You can change the available intervals in the system administration. |
When a Sensor Reports an Error |
Define the number of scanning intervals that a sensor has time to report an error before the sensor will be set to a Down status. The sensor can try to reach a device several times, depending on the setup you can specify here, to help avoid false alarms if the monitored device has only temporary issues. For previous scanning intervals with failed requests, the sensor will show a Warning status. Choose between:
Note: Sensors that monitor via Windows Management Instrumentation (WMI) always wait at least one scanning interval until they show an error. It is not possible to set a WMI sensor "down" immediately, so the first option will not apply to these sensor types (all other options can apply). Note: If a sensor has defined error limits for channels, this sensor will always be set to a Down status immediately, so no "wait" option will apply. Note: If a channel uses lookup values, the sensor will always be set to a Down status immediately, so no "wait" options will apply. |
Schedules, Dependencies, and Maintenance Window |
|
---|---|
Note: Inheritance for schedules, dependencies, and maintenance windows cannot be interrupted. The corresponding settings from the parent objects will always be active. However, you can define additional settings here. They will be active at the same time as the parent objects' settings. |
|
Schedule |
Select a schedule from the list. Schedules can be used to monitor for a certain time span (days, hours) throughout the week. With the period list option it is also possible to pause monitoring for a specific time span. You can create new schedules and edit existing ones in the account settings. Note: Schedules are generally inherited. New schedules will be added to existing ones, so all schedules are active at the same time. |
Maintenance Window |
Specify if you want to set-up a one-time maintenance window. During a "maintenance window" period, this object and all child objects will not be monitored. They will be in a paused state instead. Choose between:
Note: To terminate a current maintenance window before the defined end date, you can change the time in Maintenance End At field to a date in the past. |
Maintenance Begins At |
This field is only visible if you enabled the maintenance window above. Use the date time picker to enter the start date and time of the maintenance window. |
Maintenance End At |
This field is only visible if you enabled the maintenance window above. Use the date time picker to enter the end date and time of the maintenance window. |
Dependency Type |
Define a dependency type. Dependencies can be used to pause monitoring for an object depending on the status of another. You can choose between:
Note: Testing your dependencies is easy! Simply choose Simulate Error Status from the context menu of an object that other objects depend on. A few seconds later all dependent objects should be paused. You can check all dependencies in your PRTG installation by selecting Devices | Dependencies from the main menu bar. |
Dependency |
This field is only visible if the Select object option is enabled above. Click on the reading-glasses and use the object selector to choose an object on which the current sensor will depend. |
Delay (Seconds) |
Define a time span. After the master object for this dependency comes back to an Up status, the beginning of the monitoring of the depending objects will be additionally delayed by the time span you define here. This can help to avoid false alarms, for example, after a server restart, by giving systems more time for all services to start up. Please enter an integer value in seconds. Note: This setting is not available if you choose this sensor to be the Master object for parent. In this case, please define delays in the parent Device Settings or in the superior Group Settings. |
Access Rights |
|
---|---|
User Group Access |
Define which user group(s) will have access to the object you're editing. A table with user groups and types of access rights is shown: It contains all user groups from your setup. For each user group you can choose from the following access rights:
You can create new user groups in the System Administration—User Groups settings. To automatically set all objects further down in the hierarchy to inherit this object's access rights, set a check mark for the Revert children's access rights to inherited option. For more details on access rights, please see the section User Access Rights. |
Knowledge Base: How do I find out what OID I need to use for a custom sensor?
Knowledge Base: My SNMP sensors don't work. What can I do?
To change display settings, spike filter, and limits, switch to the sensor's Overview tab and click the gear icon of a specific channel. For detailed information, please see the Sensor Channels Settings section.
Click the Notifications tab to change notification triggers. For detailed information, please see the Sensor Notifications Settings section.
For more general information about settings, please see the Object Settings section.
For information about sensor settings, please see the following sections:
Keywords: